搜索 校内登录
  • 陈伟雄

  • 教授

电子邮箱:

所在单位: 能源与动力工程学院

学历: 博士研究生毕业

办公地点:

性别: 男

联系方式:

学位: 博士

博士生导师: 是

硕士生导师: 是

论文成果

当前位置: 中文主页 - 科学研究 - 论文成果

Simulation study on 660 MW coal-fired power plant coupled with a steam ejector to ensure NOx reduction ability

发布时间:2025-04-30
点击次数:
发布时间:
2025-04-30
论文名称:
Simulation study on 660 MW coal-fired power plant coupled with a steam ejector to ensure NOx reduction ability
发表刊物:
Applied Thermal Engineering
摘要:
A 660 MW supercritical coal-fired power plant coupled with a steam ejector is proposed to increase the
feedwater temperature, which is used to ensure the NOx reduction ability under a low load. The simulation work for the system performance under different steam sources of feedwater heater, feedwater
regenerative heating systems and steam sources of steam ejector is carried out. Results indicate that
it’s a favorable choice to increase the water temperature through adding No. 0 feedwater heater coupled
with steam ejector, because NOx removal efficiency increases from 68.97% (benchmark condition) to
74.66% under 50% THA condition, and it would improve the plant thermal efficiency while the standard
coal consumption rate would decrease 0.5 g (kW h)1. Meanwhile, results conclude that it has superior
performance than the system by No. 1 feedwater heater coupled with steam ejector. Finally, it’s found
that it is more suitable when the primary flow is from the platen superheater outlet. It also finds that
the system performance (the induced flow is from No. 1 steam extraction) is more efficient compared
with systems that the induced flow is from the cold or hot reheat steam.
合写作者:
Chen W,Zhang G, Li B, et al.
卷号:
111 (2017)
页面范围:
550-561
是否译文:
发表时间:
2016-10-08