 论文1:Effects of Turning Angle and Turning Internal Radius on Channel Impingement Cooling for a Novel Internal Cooling Structure, GT2020-16115

(此论文已被推荐至ASME期刊发表)

        Leading edge multi-channel double wall design, a novel internal cooling structure, has been put forward recently to enable higher overall cooling effectiveness with less penalty of coolant mass flow and pressure loss. Our previous work has proved the advantages of the design under operating condition relative to conventional internal cooling methods including impingement cooling and swirl cooling. Channel impingement cooling structure, which is utilized at the turning region of the leading edge, is the critical factor to realize the high cooling performance of the design. Hence, the turning angle and turning internal radius of the cooling channel are two key parameters for the novel design, and this paper focuses on the effects of these two parameters on the flow and heat transfer characteristics of the channel impingement cooling structure. Nine simplified single-channel models with different turning angles (45°, 60°, and 75°) and radiuses (0.6 mm, 0.9 mm, and 1.2 mm) were adopted to conduct the study, and the jet Reynolds number ranges from 10,000 to 40,000.

 

        The results show that the turning angle and turning internal radius affect the jet form significantly for the same mechanism. Small turning angle means large impingement, which leads to stream-wise counter-rotational vortices and high turbulence intensity, but increasing turning internal radius transfers the jet form from impingement jet to laminar layer attaching the target surface with low heat transfer. The turning internal radius has stronger effect than turning angle. With higher jet Reynolds number, both the heat transfer and total pressure loss increase dramatically, and the effects of geometrical parameters are clearer.

 

论文2:Conjugate Heat Transfer Characteristics of Double Wall Cooling on a Film Plate with Gradient Thickness, GT2020-14275

         Double wall cooling, consisting of internal impingement cooling and external film cooling, is an advanced cooling method of gas turbines. In this paper, the flow and conjugate heat transfer characteristics of double wall cooling which has a film plate with gradient thickness are analyzed numerically. The detailed overall cooling effectiveness distributions are obtained by solving steady three dimensional Reynolds-averaged Navier-Stokes equations.

In the double wall cooling scheme, seven vertical film holes and six impingement holes are staggered with same diameter (D), and the hole pitch of them are both set to 6D in flow direction and lateral direction. The gradient thickness along the flow direction is realized by setting the angle (α) between the lower surface of the film plate and the horizontal plane at -1.5 deg and 1.5 deg respectively. By comparing the results of four broadly used turbulence models with experimental data, SST k-ω is selected as the optimal turbulence model for double wall cooling analysis in this paper. In addition, the number of grids are finally determined to be 5.2 million by grid sensitivity calculation. The influence of the thickness gradient on the overall cooling effectiveness is revealed by comparing with the constant thickness film plate (Baseline 1 and 2), and all the cases are performed under four various coolant mass flow rates, which correspond to blowing ratios ranging from 0.25 to 1.5.

 

The calculated results show that the thickening of the film plate downstream is beneficial to improve overall cooling effectiveness at low blowing ratio, which is benefit from two aspects. One is the thicken film plate weakens the flow separation in film hole and velocity of film hole outlet, another is the thicken film plate makes the impingement channels convergence, and impingement cooling is strengthened to some extent. However, with the increase of blowing ratio, the increasing trend gradually weakens due to the jet-off and limited impinge ability. For thickening film plate, the variations of the double wall cooling configurations are considered at initial film plate thickness tf of 2D and 3D, it is found that the ability to improve the overall cooling effectiveness by thickening the film plate downstream decrease as the initial film plate thickness increases, which is due to the increase of heat transfer resistance, and another finding is the cooling effectiveness of downstream thickening film plate with initial thickness of 2D is higher than that of 3D, which will provide a theoretical foundation both for improving cooling performance and reducing turbine blade weight at the same time. The influence of initial impingement gap H is also observed, and the study come to the fact that the best cooling performance occurred in H=2D.