论文期刊

论文标题    Experimental investigation on vapor injection heat pump with a newly designed twin rotary variable speed compressor for cold regions
作者    Gang Yan*, Qinlei Jia, Tao Bai.
发表/完成日期    2015-11-04
期刊名称    International Journal of Refrigera
期卷    62
相关文章   
论文简介    A newly designed twin rotary variable speed compressor was adopted to improve the heating performance of a vapor injection heat pump air conditioner (HPAC) at cold regions in this study. The performances of a R410A HPAC were measured and investigated. The results showed that an optimum intermediate pressure existed to achieve the maximum heating capacity and system COP for the injection cycle, and the heating capacity was enhanced effectively by increasing compressor frequency, however, at the cost of COP decrease. Comparative research on system performances between injection and non-injection cycles indicated that the newly designed compressor could improve the heating performance of the HPAC at low ambient temperatures. Specifically, the system’s heating capacity was enhanced by 5.6%-14.4%, and COP improvement reached up to 3.5%. Vapor injection cycle was not suggested at high ambient temperatures due to its lower COP compared with non-injection cycles.